| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Process connection | Threaded connection G 1/2 sealing cone |
| Output Function | Normally open/normally closed; (parameters can be set) |
| Media | Liquid; Viscous Medium; Powder |
|---|---|
| Probe Length [mm] | 11 |
| Tank pressure[bar] | -1...40 |
| Oil Medium Temperature [°C] | -40...100 |
| Water Medium Temperature [°C] | -40...100 |
| Oil Medium temperature short time[°C] | -40...150; (1 h) |
| Water Medium temperature short time[°C] | -40...150; (1 h) |
| Connection | 1 x M12 |
|---|
| Operating Voltage [V] | 18...30 DC |
|---|---|
| Reverse polarity protection | Have |
| Measuring principle | Capacitive |
| Output Quantity | 2 |
|---|---|
| Output signal | switch signal |
| Short-circuit protection | Have |
| Overload Protection | Have |
| Max. voltage drop switching output DC[V] | 2.5 |
| DC Switch Output Permanent Current Load [mA] | 100 |
| Factory Setting | Water as the basic medium |
|---|
| Ambient Temperature [°C] | -40...85 |
|---|---|
| Storage temperature[°C] | -40...85 |
| Dimensions [mm] | Ø21.5 / L = 99 |
|---|---|
| Material (Wetted Parts) | PEEK;Surface roughness: Ra < 0.8 μm / Rz < 4 μm |
| Pack quantity | 1 item |
|---|